SPARES |
PRESSURE SWITCHESModern combustion equipment depending on type and application is fitted with pressure switches with various functions. Many types of pressure switches are manufactured, with various pressure ranges and complying with many technical and safety standards. Without doubt the most common application for a pressure switch is for monitoring that the burner combustion air supply is adequate to ensure complete and proper operation of the burner. Insufficient air supply may result in poor and inefficient combustion of the fuel, resulting in fuel wastage and the production of carbon monoxide and carbon particles in the products ofcombustion. The application of pressure switches is the preferred method of monitoring the air supply which should be checked both during normal combustion periods and combustion chamber pre-purge and post-purge periods. The failure of process air flow through direct fired and indirect fired heaters and most types of process plant will cause damage to the plant if the combustion equipment continues to operate. Pressure switches are fitted to most type of plants to monitor correct process air flow and shut down the plant in the case of air flow failure. In most applications differential pressure switches are used. Failure of gas supply pressure may cause flames to extinguish or at least combustion quality to suffer.
It is common for combustion plant to be fitted with a pressure switch to monitor this possible problem. For more information regarding the design, structure and application of pressure switches consult the Technical (controls) section of this web-site. |
CONTACT COMTHERM BY E-MAIL REQUEST A SPARES QUOTATIONMANUFACTURERS
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Actu Pressure Switches
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Black Pressure Switches
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Delta Pressure Switches
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Dungs Pressure Switches
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
  |
Dwyer (Chicago) Pressure Switches
|
  |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Honeywell Pressure Switches
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Kromschroder Pressure Switches
|
|











.jpg)
.jpg)
.jpg)