FLAME SAFTEY CONTROLS & EQUIPMENT

To avoid situations were explosive mixtures of fuel and combustion air can occur without proper and correct ignition, modern burners are fitted with flame sensing and start-up sequencing equipment.

The main feature of this equipment is to prove the correct operation of the combustion air supply fan, the start and main gas solenoid valves and the ignition equipment in a pre-set order.

The timings pre-set into the equipment are designed to pre-purge and post-purge combustion chambers so combustible mixtures cannot occur before the controlled ignition period.

The flame sensing element of the equipment ensures that should a flame be extinguished by fault, then the electrical supply to the fuel solenoid valves will be cut off.

Various types of flame sensing methods have been used from heat sensing and thermoelectric devices to electronic units.
Many gas burners utilise the flames ability to be used as an electrical rectifier as the system of detection.

When applying flame safety equipment, care should be taken that the equipment installed is suitable for use with the fuel supply and electrical supply used and complies with local statutory requirements.

If in doubt consult Comtherm technical staff.

For more information regarding the design, structure and application of Flame Safety equipment consult the Technical (controls) section of this web-site.

CONTACT COMTHERM BY E-MAIL REQUEST A SPARES QUOTATION

MANUFACTURERS

» Fireye
» Honeywell
» Landis & Gyr
» Satronic
» Siemens

Fireye Flame Safety Equipment

Model Type          

box

box

box

Honeywell (Satronic) Flame Safety Equipment

Model Type          

box

box

box

box

box

Siemens (Landis & Gyr) Flame Safety Equipment

Siemens Flame Safety Control Box Operating Voltage Operating Frequency Protection Weight Operating Temp.
LFL1.335. A27 230 50/60 IP40 1000g -40 to +70
LFL1.335. A17 110 50/60 IP40 1000g -40 to +70
LFL1.322. A27 230 50/60 IP40 1000g -40 to +70
LFL1.322. A17 110 50/60 IP40 1000g -40 to +70
LFL1.622. A27 230 50/60 IP40 1000g -40 to +70
LFL1.622. A17 110 50/60 IP40 1000g -40 to +70
LFL1.635. A27 230 50/60 IP40 1000g -40 to +70
LFL1.635. A17 110 50/60 IP40 1000g -40 to +70
LFL16.335. A27 230 50/60 IP40 1000g -40 to +70
LFL16.335. A17 110 50/60 IP40 1000g -40 to +70
Siemens Flame Sensors Operating Voltage Operating Frequency Protection Weight Operating Temp.
QRA2 U.V. N/A 50/60 IP40 60g -20 to +60
QRA10 U.V. N/A 50/60 IP54 740g -20 to +60
QRA53. C27 230 50/60 IP54 900g -20 to +60
QRA53. C17 110 50/60 IP54 900g -20 to +60
QRA55. C27 230 50/60 IP54 900g -20 to +60
QRA55. C17 110 50/60 IP54 900g -20 to +60
Siemens Accessories      
AGM410490550 Connection base for LFL    
AGM17 Connection base for LGK    
AGM19 Plug & 2 metre lead for QRA53 & 55    
AGG02 Standard Quartz lens    
AGG03 Magnifying Quartz lens    
AGG06 Quartz lens adaptor nut    
AGG16. C Mounting adaptor for QRA53 & 55    
AGR 450240657 Replacement bulb for QRA2, 10, 53 & 55.    

box

box